How Long After Nitrogen Purge Can Sensor Performance Be Tested?

Apr 24, 2026

Leave a message

After nitrogen purging, the sensor must be dried and cooled to room temperature before performance testing. This is typically done within 6-7 hours after purging. Especially in the high-temperature and high-humidity environment of Wuhan, it is essential to ensure that low-temperature baking (60°C/4-6 hours) is completed and the sensor has cooled naturally before performance testing can begin.

1. Testing Timing: After the Purging + Baking + Cooling Closed Loop

Immediate Baking After Purging: Start low-temperature baking at 60°C within 30 minutes of purging and continue for 4-6 hours.

Natural Cooling After Baking: Cool to room temperature in a dry environment (approximately 30-60 minutes) to prevent condensation.

Final Testing Timing: Complete all procedures and begin testing within 6-7 hours after purging.

 

2. Required Test Items and Acceptance Standards

Test Item

Acceptance Standard

Test Tool

Insulation Resistance

>100MΩ (500VDC)

Megohmmeter

Loop Resistance

2~10Ω

Multimeter

Zero-Point Calibration Offset

<0.3℃

HMI System

Power-On Stability

No drift (<0.5℃/h), no burrs

30-minute trial run

Judgment Criteria: If any item fails to meet the standard, it is judged as recovery failure, and the sensor needs to be replaced.

3. Risks of Delayed Testing

Premature Testing (Without Cooling): Condensation may occur during the cooling process, resulting in a falsely low insulation resistance, which may be mistakenly judged as unrecoverable.

Delayed Testing (>24 hours): If not stored in a sealed container, the sensor may be exposed to moisture again, affecting the accuracy of the test.