How often should the status check be performed after RC parameters are locked?

Aug 06, 2026

Leave a message

I. Basic Grade Daily Inspection Cycle

High-precision optical-grade injection molding process: Perform an RC lock status check once daily after the morning shift starts, and complete a full verification of RC parameter performance weekly.

Medium-precision engineering part injection molding process: Perform an RC lock status check every 3 days, and complete a full verification of RC parameter performance every 2 weeks.

General injection molding process for ordinary structural parts: Perform an RC lock status check weekly, and complete a full verification of RC parameter performance monthly.

 

II. Cycle Adjustment Rules under Special Operating Conditions

24-hour continuous full-load production scenario: The RC lock status check cycle for all processes is uniformly shortened by 50% to avoid accelerated RC hardware aging and parameter drift caused by long-term power-on operation.

Strong electromagnetic interference workshop scenario: The full verification cycle of RC parameter performance for all processes is uniformly shortened by 50% to adapt to changing interference characteristics on site.

In cleanroom low-interference scenarios, the daily inspection cycle for all processes can be extended by 50%, reducing unnecessary maintenance

costs while ensuring accuracy.

 

III. Mandatory Conditions for Triggering Immediate Specialized Inspections

If a high-power frequency converter, servo motor, or other strong interference source is added to the workshop, significantly altering the electromagnetic environment, a full verification of RC parameters must be performed immediately.

After maintenance and rewiring of the temperature sensing lines in the hot runner system, a specialized inspection of the RC lockout status and parameter performance must be performed immediately.

If faults such as temperature reading jumps or uncontrolled temperature rise overshoot occur, a specialized inspection of RC parameters must be performed immediately after the fault is repaired to eliminate potential drift hazards.