How to Determine if a Hot Runner System Has Good Insulation

Apr 24, 2026

Leave a message

The key indicator for determining if a hot runner system has good insulation is an insulation resistance >10MΩ under high-temperature operating conditions. This should be combined with visual inspection, electrical testing, and a comprehensive evaluation of historical data to ensure the system's safe and stable operation.

1. Core Judgment Criterion: Insulation Resistance Value

Ideal State: Under high-temperature operation (150℃~400℃), the insulation resistance should be >50MΩ;

Minimum Acceptance: Not less than 10MΩ. A value below this indicates a risk of leakage;

Cold State Reference Value: At room temperature, the insulation resistance should be >100MΩ, serving as a preliminary judgment basis before commissioning.

Note: For every 10℃ increase in temperature, the insulation material resistance decreases by approximately half. The actual insulation performance needs to be dynamically evaluated in conjunction with temperature.

 

2. Judgment Steps and Key Operating Points

Steps

Operating Instructions

Power Off and Cooling

Turn off the heating power and wait for the system to cool to <80℃, ensuring safe operation.

Visual Inspection

Check the junction box, plug, and heating rod ports for signs of burning, carbonization, or moisture condensation.

Cleaning

Wipe the terminals with anhydrous alcohol to remove oxide layers and dirt, avoiding poor contact that could interfere with the test.

Applying Test Voltage

Use a 500VDC megohmmeter. Connect the L terminal to the heating circuit and the E terminal to the casing or ground wire.

Reading Stable Value

Maintain the test for 1 minute and record the final stable resistance value.

Data Comparison

Compare with historical records. If the sudden drop exceeds 50%, internal aging or moisture should be investigated.

Risk Warning: If the measured resistance is <1MΩ, it indicates a serious insulation failure. Do not power on; disassembly and repair are necessary.

 

3. Auxiliary Judgment Methods

Power-on Operation Monitoring: Observe for abnormal tripping, large current fluctuations, and inaccurate temperature control; Use an infrared thermal imager to detect localized overheating points, which may be precursors to leakage.