How to Differentiate Between Teflon-Coated Corrosion-Resistant Thermocouples and Fixed-Flange Probe-Type Platinum Resistance Thermometers

Jul 19, 2020

Leave a message

In the field of industrial temperature measurement, Teflon-coated corrosion-resistant thermocouples and fixed-flange probe-type platinum resistance thermometers are two common types of temperature sensors. They have significant differences in structural design, working principles, performance characteristics, and application scenarios. The following systematic comparison will highlight their core differences.

I. Differences in Structural Design and Installation Methods

1. Teflon-Coated Corrosion-Resistant Thermocouple

The core features of a Teflon-coated corrosion-resistant thermocouple are its Teflon coating protection and bimetallic wire structure. It typically uses a Teflon (polytetrafluoroethylene) sheath to cover a metal protective tube, with two different metal wires (such as nickel-chromium and nickel-silicon) welded together inside to form the measuring end. The Teflon sheath has excellent chemical stability and can resist corrosion from strong acids, strong bases, and organic solvents, making it suitable for corrosive environments in chemical and pharmaceutical industries. Its installation method is usually threaded connection or flange fixing, ensuring a tight fit with the equipment surface to improve measurement accuracy and response speed. For example, in a chemical reactor, the Teflon sheath protects the thermocouple from corrosive media, while the flange connection allows for quick installation. Its structural design emphasizes the corrosion resistance of the sheath and the independence of the bimetallic wires. The Teflon sheath reduces the impact of environmental factors on measurement accuracy and enhances resistance to mechanical shock. However, the installation process requires ensuring that the sheath is in complete contact with the surface of the object being measured, which increases the complexity of installation, and the bimetallic wires may oxidize in high-temperature environments, affecting long-term stability.

2. Fixed-Flange Probe-Type Platinum Resistance Thermometer

The core features of a fixed-flange probe-type platinum resistance thermometer are its fixed flange connection and platinum wire winding structure. It typically uses a fixed flange (such as DN50) to be bolted to the surface of the object being measured for stable installation. Inside, platinum wire is wound on a ceramic or mica frame to form the temperature sensing element. The fixed flange design ensures a rigid connection between the probe and the equipment surface, making it suitable for high-pressure or applications requiring long-term stable measurement. For example, in the food processing or pharmaceutical industries, the fixed flange design ensures that the probe remains stable on high-pressure pipelines, reducing the impact of vibration on measurements. Its structural design emphasizes the rigid connection of the flange and the stability of the platinum wire. The fixed flange design reduces the influence of environmental factors on measurement accuracy while enhancing resistance to mechanical shock and chemical corrosion. However, the installation process requires ensuring that the flange is completely flush with the surface of the object being measured, which increases the complexity of installation. Furthermore, the rigid connection of the fixed flange may limit flexibility in scenarios requiring frequent adjustments.

II. Differences in Working Principles

1. Working Principle of Teflon-Coated Anti-Corrosion Thermocouples

Thermocouples are based on the Seebeck effect, where two different metal conductors generate a thermoelectric potential difference under a temperature gradient. When two metal conductors are connected to form a closed circuit, and the two junctions have different temperatures, an electromotive force is generated in the circuit. The magnitude of this force is related to the material properties and the temperature difference between the junctions. By measuring the electromotive force, the temperature value can be indirectly calculated. Thermocouples have high sensitivity; a 1°C temperature change results in an output potential change of approximately 5-40 microvolts. Their structure is simple, with no moving parts, making them suitable for high-temperature, high-pressure, and highly corrosive environments. The addition of a Teflon coating further expands their application range, allowing them to operate stably in highly corrosive environments.

2. Working Principle of Fixed Flange Probe-Type Platinum Resistance Thermometers

Platinum resistance thermometers are based on the characteristic that metal resistance changes with temperature. Their resistance value has a non-linear relationship with temperature and needs to be determined by consulting a table or using a formula (e.g., Pt100 has a resistance of 100Ω at 0℃, and the resistance value increases linearly with increasing temperature). Platinum resistance thermometers have high sensitivity; a 1°C temperature change results in a significant change in resistance value. Their structure is simple, with no moving parts, making them suitable for precise measurements at medium and low temperatures (-200℃ to 600℃), but strong magnetic fields or mechanical vibrations should be avoided to prevent affecting measurement accuracy. The fixed flange design allows them to maintain stable measurement performance even in high-temperature environments. III. Identification Methods

1. Appearance Inspection

Teflon-sheathed corrosion-resistant thermocouple: The head is usually covered with a Teflon sheath, and the inside consists of two different metal wires welded together. The sheath is white or transparent and has a smooth surface.

Fixed flange type probe platinum resistance thermometer: The head is usually covered with a metal protective tube, and the inside is a temperature-sensing element made of platinum wire. The fixed flange is secured to the surface of the object being measured with bolts.

2. Wiring Method

Teflon-sheathed corrosion-resistant thermocouple: Uses a two-wire system (positive and negative), the junction box is marked "TC+" and "TC−", and the leads are usually red (positive) and black/blue (negative).

Fixed flange type probe platinum resistance thermometer: Uses a three-wire system (R1, R2, R3), the junction box is marked "R1", "R2", "R3", and the leads are usually red, white, and yellow.

3. Multimeter Measurement

Teflon-sheathed corrosion-resistant thermocouple: The resistance value is very small, usually only a few ohms.

Fixed flange type probe platinum resistance thermometer: The resistance value is approximately 100 ohms at room temperature (Pt100).

IV. Differences in Application Scenarios

1. Teflon-sheathed corrosion-resistant thermocouple

Highly corrosive environments: Suitable for chemical, pharmaceutical, and other industries. The Teflon sheath can resist corrosion from strong acids, strong bases, and organic solvents.

High-temperature environments: Performs stably in high-temperature measurements, suitable for high-temperature equipment such as reactors and pipelines.

2. Fixed flange type probe platinum resistance thermometer

Scenarios requiring fast response and close contact: For example, in the food processing or pharmaceutical industry, the fixed flange design ensures full contact between the probe and the equipment surface, improving measurement accuracy and response speed.

Medium and low-temperature environments: Performs excellently in indoor or low-pressure scenarios, such as HVAC systems.

info-1600-1103

Send Inquiry
Contact usif have any question

You can either contact us via phone, email or online form below. Our specialist will contact you back shortly.

Contact now!