How to Judge the Quality of Magnesium Oxide Insulation Layers

May 07, 2026

Leave a message

The core method for judging the quality of magnesium oxide insulation layers is to test their purity, insulation resistance, and physical structural integrity. High-quality magnesium oxide insulation layers should possess high purity, excellent insulation performance, and a dense and uniform filling structure.

 

1. Key Quality Indicators

Purity (≥99.9% is excellent)

High-purity magnesium oxide (MgO) has low impurity content, effectively reducing the risk of leakage caused by conductive impurities such as Fe₂O₃ and CaO;

High-quality products meet the standard of HG/T 6445-2025, with Cl⁻ ≤0.05% and SO₄²⁻ ≤0.03%;

The supplier can be requested to provide a component analysis certificate as verification.

Insulation Resistance (≥100 MΩ is acceptable) Cold insulation resistance measured using a 2500V megohmmeter:

≥500 MΩ: Brand new, high-quality condition;

100–500 MΩ: Normal and usable;

<10 MΩ: Unacceptable quality or severely degraded.

Hot test (test after 30 minutes of operation with power off): ≥200 MΩ.

Fill Density and Structural Uniformity

Fill density should be between 2.8–3.2 g/cm³. Too low a density can easily create voids, leading to localized overheating.

X-ray or cross-sectional inspection confirms the absence of off-center cores, voids, or delamination.

High-quality products undergo high-frequency vibration compaction + hydraulic pressing processes, resulting in a stable structure.

 

2. Appearance and Process Characteristics Identification

Characteristics

High-Quality Performance

Low-Quality Performance

Surface Crystallization Morphology

Magnesite-type crystals, dense and stable

Seawater-crystal type, easily absorbs moisture

Particle Size Distribution

Mainly 100–200 mesh, uniform

Too coarse or too fine, affects thermal conductivity

Sealing Performance

Ceramic adhesive or metal seal, IP65 or higher protection

Ordinary silicone seal, prone to aging and cracking

Wire Outlet Treatment

Multi-layer protection: waterproof tape + heat shrink tubing + silicone coating

Single-layer wrapping, easily affected by moisture

If white powder (Mg(OH)₂), bulging of the casing, or corrosion of the wiring terminals is found, it indicates poor hydration resistance or poor sealing of the material.

 

3. Performance Testing and Verification

Test Item

Acceptance Standard

Test Significance

Cold Withstand Voltage Test

AC 2000V, no breakdown after 1 minute

Verifies initial insulation strength

Hot Insulation Resistance

≥200 MΩ (after operation)

Verifies stability at high temperatures

Hydraulic Test

≥200 MΩ after 48 hours at 40℃ and 95% RH

Simulates high humidity conditions

Life Test

Insulation resistance decreases by <30% after 15000 hours of continuous operation

Assess long-term reliability

It is recommended to use products certified according to JB/T 2379-2016 and request the factory test report.